Preventing Cable Leaks

In an increasingly organized industry, Radiodetection Cable Avoidance Tools, the next generation of CAT4™ and Genny4™, build on over 40 years of CAT and Genny expertise to enable operators to find programs from the ground faster, more often.
These two innovative tools have been designed to offer minimal change capabilities to business practices and training requirements one step change.

The CAT4 and Genny4 series are designed to assist in reducing the risk of injury to personnel and utility damage by avoiding buried cables and pipes during excavation. It is designed to detect CAT4 signals - be it generated by Genny4, from the free array of Sondes (Mouse) and accessories designed to natively radiate metallic services, or provide the location of non-conductive services.

CAT4 and Genny4 Radiodetection is the most advanced CAT and Genny system to date designed to offer optimum performance, a high level of security, advanced features and competitive cost of ownership.

General view

Faster Detection, More Detection
The CAT4 digital platform offers a highly refined, specifically designed to assist the operator, find capabilities more can find programs from the ground. CAT4 Evasion Mode™ allows the operator to control the intended dig area for Power, Radio and Genny signals, and detect programs found in a single scan. Features such as a fast peak response on a buried conductor and an operator's 'water level trace' bargraph of the zero-in point.
Genny4 Signal Generator lets you find simultaneous dual frequency signal output. Besides the familiar 33kHz for general purpose finds, the Genny4 transmits a secondary high frequency signal, designed to facilitate the location of small diameter cables such as telecom and street lighting including Spurs. For difficult location determinations, the power-boosting function also enables the find signal and deep travel and double-over programs easily.

CAT 4 SERIES Technical Specifications

Radiodetection's range of Cable Avoidance Tools, CAT4 and Genny4, builds on operators' over 30 years of Cable Avoidance expertise to find programs from the ground faster, more often.
An innovative range of tools, business practices and training requirements are designed to deliver minimal change capabilities one step chang.
More Detection, faster detect
CAT4 Evasion Mode™ allows the operator to control the intended dig area for Power, Radio and Genny4 signals and detect found programs in a single scan. Histogram 'water level trace' quickly provides point above zero and user
An embedded conductor. Genny4 provides simultaneous dual frequency
Signal output. In addition to general purpose finds the familiar 33 kHz signal, the Genny4 special transmits Small Diameter Locate frequency makes it easy to locate from utilities such as telecom and street lighting including Spurs. For those who find it difficult, the Signal Boost function allows Genny4 signals to travel further and deeper, and onto programs that double easier.
CAT4 Dynamic Overload Protection feature automatically filters high
interference, allowing operators to continue working even in electrically noisy areas such as substations and under high voltage cables - and requires no input from the operator.

Dig more secure
As a safety critical tool, CAT4 and Genny4 offer a number of features designed to support their safe operation and help to bring down utility strike rates. While StrikeAlert™ warns the operator of vehicles from shallow soil, SWING™ alerts to incorrect usage habits, courage corrective action. The eC.A.T4™ and gC.A.T4™ models feature on-board data collection, logging every second of key Locate parameters to help identify training needs. The GC.A.T4 range contains an internal GPS/GNSS receiver that adds spatial data to log records showing not only how the operator was working, but also where CAT was used. All CAT4 units are quipped with Radiodetection's proprietary eCert™ technology, which provides a comprehensive assessment of the unit's hardware and software using an internet connection to Radiodetection, and can be used to extend the validity of CAT4's
demand1 on the calibration certificate. 1 Detailed purchase may be required.
Easy to use and promotion
CAT4 and Genny4 were first introduced by Radiodetection in the mid-1980s and are designed to maintain the familiar CAT operating interface and offer full reverse-compatibility. For example, all Genny3 accessories are compatible with Genny4.
Radiodetection offers comprehensive training options for operators, administrators and educators to promote best operating practices and supports their management
Cable Avoidance is in charge. Please contact your local office or representative for more information.
Data Collection / Log
On-board memory allows data2 to be stored on a year's worth of eC.A.T4 and gC.A.T4 series products. This data can be backed up to a PC at any time, giving virtually unlimited record keeping throughout the life of the product. The data received can be analyzed, locally or remotely, to assist in ensuring compliance and identifying training needs.
Logged factors include:

*Genny / Power / Radio signal strength
*Date and time of survey
* StrikeAlert / Swing warning states Speed over ground3
* Location of the survey (Latitude / Longitude) 3
* Bargraph reading
* Sensitivity control setting
* Depth measurements made
* Battery status
* Last/next calibration date
* Dynamic Overload Protection / signal overload
* Usage Angle
* Number of Satellites Received3 n
* Sound status

8 hours of use per day, 5 days per week based on 2
3 gC.A.T4 models

eCert - Remote calibration verification
eCert offers an innovative calibration option intended for remote calibration tests as part of an annual service regimen. Active via CAT Manager PC software, eCert provides key insertion circuitry within CAT4, fast comprehensive and convenient testing, and verifies results against original factory calibration using an internet connection to Radiodetection. After passing an eCert test, this CAT4 can be printed or saved in a Radiodetection Calibration Certificate. For a complete care package, Radiodetection also offers detailed
Factory assisted service and recalibration options, including full mechanical integrity inspection and function tests.

Small Cable Fixing
Simultaneous dual-frequency and simple, intuitive methods have been superseded by CAT4 and Genny4 to assist users of CAT4 and Genny4 to locate Small Diameter cables such as twisted-pair telecom Spurs and drop-off feeds, to locate and risk a common strike.
Indicator and CALSAFE™ due to service
Annual service and calibration is key to ensuring CAT operators can operate safely and with confidence in their equipment. To support this, the eC.A.T4 and gC.A.T4 models provide a 31-day service due countdown alert at start-up. CALSafe - can be set to automatically disable active units above the end of the defined calibration interval to comply with individual company policies. The required interval between services can be customized using CAT Manager software for anything up to a year.

SWING alert
Radiodetection CATS is designed to respond extremely quickly to equalize small detectable underground signals. Radiodetection's research into underground signal detection has shown that an operator's ability to identify these embedded programs is directly affected by careless work practices such as excessive or fast rocking. Also to reduce the risks of utility strikes, the eC.A.T4 and gC.A.T4 models are equipped with Sensors that detect misuse and also alert the user with a warning stored in the data log.

Evade Mode
Evade Mode Power speeds up the pre-dig scanning process by calling Radio and Genny signals at the same time. CAT4 Avoidance Mode offers fully controlled responses, allowing operators to quickly identify embedded program and trace throughout an area. True Voice enables operators to distinguish between individual signals and programs, maximizing find speed while maintaining sound safety.

CAT Manager Software
CAT4 discovery is supported by the dedicated CAT Manager program. This Windows® PC application allows plant, fleet and site administrators to quickly upgrade CAT4, use data4 download and perform an eCert test
Map systems as software logs or export data to files in KML, CSV or XLS format. To match your working preferences, you can disable CAT Manager or enable CAT4 features like depth estimation and alerts.
User editable fields allow plant/fleet codes and other details to be stored on the unit, simplifying records and traceability. 4 eC.A.T4 and gC.A.T4 models

Real Sound
The audio signals emitted by CAT4 are derived from detection signals. Both Radio, Power, and Genny signals can be easily distinguished from each other and from background noise, aiding in identification from target vehicles and aiding differentiation from closely cooperating vehicles.
Genny4 signal boost
Besides the familiar standard power mode, the Genny4 provides the Signal Boost feature that increases the output signal by a factor of 10, enabling operators to locate deep programs and over great distances.

Get Info