Adres: 1234. CADDE (ESKİ 57) 125
Tel 1: 0 (312) 385 11-02
Tel 2: 0 (312) 240 55-54
Faks:
Email 1: info@enermak.com
Web: https://www.enermak.com/
Always the right blow...
ISOTEST act 35
... in-plant holiday detector with high voltage pulse technology
ISOTEST act 35
Application
Non- or lightly conductive materials and coatings such as 3-ply PE/PP can be reliably tested for pores or other damage. The same applies to foils and rubber coatings, which is valid for non-destructive testing with minimal stress from the material.
All ISOTEST ® holiday detectors have undergone extensive testing in the field of safety and EMC. All of them carry the CE label and fulfill all relevant standards and technical requirements (DIN EN / ISO / DVGW etc.)
You can count on...
-A compact "all-in-one" device (in one compact body control unit and high voltage generator)
-Continuous work (three shifts)
-Porosity/leakage testing of all non- or slightly conductive materials
-External on/off test voltage
-Increased operator safety - thanks to the combination of impulse voltage and smart power control
Stable test voltage, even under harsh conditions, guaranteed by load-dependent regulation of energy
- Highest test rates possible with optimized pulse repetition frequency
- detecting and imaging even the smallest pores and cavities by integral evaluation process - with minimal substance stress
-DC devices have a latent risk of electrostatic charges, which are excluded by the use of impulse technology
-testing fully coated test objects - even without direct ground - made possible with the "Phantom-Grounding" option (possible with impulse voltage)
technical data
Test voltage: 5 - 2.5 kV on request (standard) additional test voltages 30 kV in steps
Test channels: Up to 6 test channels (master/slave mode)
Voltage supply: 100 - 240 VAC / 47 - 63 Hz (Wide input range) or 90-375 VDC
Power supply (load dependent): <100 W
Inputs: test voltage external activation via switch contact or 24 VDC
Outputs:
pore alarm changeover-floating
Change-over-floating for operational monitoring
Working time: three shifts
Test speed : up to 300 mm / s :
Test voltage regulation: load dependent adaptation (continuous)
Selectable filter settings to perfectly match individual test conditions: load adaptation
Porosity Indication:
On-screen audio signal
-potential free contact for external signaling units
Other viewing options:
-pore counter
-Multilingual menu
Test duration-indication (current and total)
-indicator to your next scheduled service date
-Permissible ambient temperature: 0 °C ... +50 °C (thermal constant > 10 K/h)
Air humidity: max. 60% relative air humidity at 30°C
Scope of delivery:
-in-plant holiday detector ISOTEST action 35
-high voltage cable
-works / calibration certificate
-User guide
Features
•Testing of dirty, damp and even slightly conductive surfaces
•No Static loading
6 test channels per minute - sync various devices (Master / Slave mode)
"Phantom-Grounding" - no direct grounding required
•External on / off test voltage
• Adjustable sensitivity and filter functions